International Journal of Energy Science and Engineering
Articles Information
International Journal of Energy Science and Engineering, Vol.2, No.2, Mar. 2016, Pub. Date: Jul. 27, 2016
Effect of Polypropylene Fiber on Properties of Mortar
Pages: 8-12 Views: 3520 Downloads: 3803
Authors
[01] Salahaldein Alsadey, Faculty of Engineering, Department of Civil Engineering, Bani Waleed University, Beni Walid City, Libya.
Abstract
This paper investigates on analyzing the effects of use of Polypropylene fiber in the mechanical properties of cement mortar. An experimental study was conducted on the cement mortar reinforced by the different percentages of polypropylene fibre (0, 0.5,1 & 1.5%). The essential objective of this work is to study the mechanical properties of cement mortar containing different percentages of polypropylene fiber. Different tests have been done to determine some aspects namely the flow table test and compressive strength at age of curing 28 days was conducted on reference and polypropylene fiber reinforced mortar specimens. The results show that the use of polypropylene fiber gives an unambiguous improvement in these properties and thus the optimum percentages for this fiber have been taken into consideration. The results show a significant increasing in compressive strength with the increment of fibers content in cement mortar.
Keywords
Mortar, Polypropylene Fiber, Cement, Compressive Strength
References
[01] Salahaldein Alsadey (2016) “Effect of Polypropylene Fiber Reinforced on Properties of Concrete”. Journal of Advance Research in Mechanical and Civil Engineering.
[02] F. Burak, S. Turkel & Y. Altuntas "Effects of steel fiber reinforcement on surface wear resistance on self-compacting repair mortar", Cem. & Conc. Comp.; 29, 2007, pp. 391-396.
[03] L. Gang, K. Wang & T. J. Rudolphi "Modeling reheological behavior of highly flowable mortar using concepts of particle and fluid mechanics", Cem. & Conc. Comp.; 30, 2008, pp. 1-12.
[04] H. Okamura, & M. Ouchi "Self compacting concrete", J. Adv. Concr. Technolgy, 1(1); 2003, pp. 1-15.
[05] K. H. Khayat, R. Morin "Performance of self-consolidating concrete used to Repair parapet wall in Montreal", Proceedings of the first north American conference on the design and use of self-consolidating concrete, 2002, pp. 475-481.
[06] ACI Committee 308, Standard Practice for Curing Concrete (308R-92), ACI Manual Concrete Practice, American concrete institute, Farmington Hill, MI, pp. 10-16, 1997.
[07] Khaliq, W., and Kodur, V., “Thermal and Mechanical Properties of Fiber Reinforced High Performance Self-consolidating Concrete at Eleavated Temperatures,” Cem. Concr. Res., Vol. 41, No. 11, pp. 1112-1122, 2011.
[08] Kerans, R. J., and Parthasarathy, T. A., “Theoretical Analysis of the Fiber Pullout and Pushout Tests” J. Amer.Ceramic Soc., Vol. 74, No. 7, pp. 1585-1596, 1991.
[09] Sanjuan, M. A., Andrade, C., and Bentur, A., “Effect of Crack Control in Mortars Containing Polyethylene Fibers on The Corrosion of Steel in A Cementitious Matrix,” ACI Mater., Vol. 94, No. 2, pp. 134-141, 1997.
[10] Banthia, N., and Gupta, R., “Influence of Polypropylene Fiber Geometry on Plastic Shrinkage Cracking in Concrete,” Cem. Concr. Res., Vol. 36, No. 7, pp. 1263-1267, 2006.
[11] Ward, R. J., and Li, V. C., “Dependent of Flexural Behavior of Fiber Reinforced Mortar on Material Fracture Resistance and Beam Size,” ACI Mater., Vol. 87, No. 6, pp. 627-637, 1990.
[12] Singh, S., Shukla, A., and Brown, R., “Pullout Behavior of Polypropylene Fibers From Cementitious Matrix,” Cem.Concr. Res., Vol. 34, No. 10, pp. 1919-1925, 2004.
[13] Barluenga, G., “Fiber-Matrix Interaction at Early Ages of Concrete with Short Fibers,” Cem. Concr. Res., Vol. 40, No.5, pp. 802-809, 2010.
[14] Wang, J. Y., Banthia, N., and Zahang, M. H., “Effect of Shrinkage Reducing Admixture on Flexural Behaviors of Fiber Reinforced Cementitious Composites,” Cem. Concr. Compos., Vol. 34, No. 4, pp. 443-450, 2012.
[15] Soroushian, P., and Ravanbakhsh, S., “Control of Plastic Shrinkage Cracking with Specialty Cellulose Fibers,” ACI Mater., Vol. 95, No. 4, pp. 429-435, 1998.
[16] Song, P. S., Hwang, S., and Sheu, B. C., “Strength Properties of Nylon-and Polypropylene Fiber-reinforced Concrete.” Cem.Concr. Res., Vol. 35, No. 8, pp. 1546-1550, 2005.
[17] Sun W., Chen H., Luo X., Qian H., The effect of hybrid fibers and expansive agent on the shrinkage and permeability of high performance concrete, Cement and Concrete Research, 2001, 31, 595-601.
[18] Toledo Filho R. D., Sanjuan M. A., Effect of low modulus sisal and propylene fibers on the free and restrained shrinkage of mortars at early age, Cement and Concrete Research, 1999, 29, 1547-1604.
[19] Toutanji H. A., Properties of polypropylene fiber reinforced silica fume expansive-cement concrete, Construction and Building Materials, 1999, 13, 171-177.
[20] Linfa Y., Pendleton R. L., Jenkins C. H. M., Interface morphologies in polyolefin fiber reinforced concrete composites, Composite Part A, 1998, 29(A), 643-650.
[21] Holmer S. J., Vahan A., Transition zone studies of vegetable fiber-cement paste composites, Cement and Concrete Composites, 1999, 21, 49-57.
[22] Sicka Company, “Technical Data Sheet Catalogue”.
[23] The American Concrete Institute (ACI 211.1-91) Standard P "Standard Practice for selecting Proportions for Normal, Heavyweight, and Mass Concrete ", ACI Manual of Concrete Practice 2000, Part 1: Materials and General Properties of Concrete.
[24] ASTM C230 "Standard Specification for Flow Table for Use in Tests of Hydraulic Cement ". Annual book of ASTM standard; 2002. PA, www.astm.org.
[25] ASTM C109 "Standard Test Method for Compressive Strength of Hydraulic Cement Mortars Using 50mm Cube Specimens ". Annual book of ASTM standard; 2002.
[26] E. T. Dawood & M. Ramli. “Development of high strength flowable mortar with hybrid fiber” Construction and Building Materials Journal 2010, 24 (6), 2010, 1043–1050.
[27] B. Chen & J. Liu “Residual strength of hybrid-fiber-reinforced high-strength concrete after exposure to high temperatures” Cement & Concrete Research; 34, 2004. pp. 1065-69.
[28] ASTM C192/C192M-02, “Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory”, Annual Book of ASTM Standards, Vol.04.02, 2003; pp. 126-133.